Particle Counter

A particle counter is a utilizable actualize for observing indoor air quality (IAQ) in cleanrooms and work environments, as a molecule counter estimates the grouping of particles noticeable all around. While a molecule counter won't identify specifically what sorts of residue or particulates are available noticeable all around, a particle counter will distinguish what number of airborne particles of a specific size are available in the earth. An end is then drawn predicated on the kenned materials in the region and the relating airborne molecule sizes of those materials. 

​ 

The idea of molecule checking is predicated upon either light dissipating, light obscuration, or direct imaging. A high power light source is used to enlighten the molecule as it goes through the location chamber. The molecule goes through the light source (commonly a laser or incandescent lamp) and on the off chance that light dispersing is used, at that point the diverted light is identified by a photograph indicator. In the event that immediate imaging is used, an incandescent lamp lights up particles from the back inside a cell while a top-notch, high amplification camera records passing particles. The recorded video is then broken down by PC programming to evaluate molecule properties. On the off chance that light blocking (obscuration) is used the loss of light is recognized. The sufficiency of the light dissipated or light blocked is measured and the molecule is checked and classified into institutionalized tallying containers. The picture to the correct shows a light dissipating molecule counter graph. More data about kinds of molecule counters and sorts of molecule recognition follow right now. 

​ 

​Direct imaging molecule checking utilizes the use of a high goals camera and a light to recognize particles. Vision predicated molecule estimating units get two-dimensional pictures that are examined by PC programming to acquire molecule size evaluation in both the research facility and on the web. Alongside molecule size, shading and shape examination can withal be tireless.

Particle Counter Meter Suppliers in Jharkhand | Particle Counter Meter Suppliers Bihar | Particle Counter Meter Suppliers in India

Atomic Absorption Spectrophotometer | Digital Multimeter | Concrete Moisture Meter | Gloss Meter | Gas Detector | High-Speed Camera | Infrared Thermometer | Microscope | pH Meter | Particle Counter | Power Supply Unit | Paperless Recorder | Spectrophotometer | Torque Meter | Thermometer | Viscometer | Water Analysis Meter

 
Particle Counter PCE-PCO 1
PCE-PCO 1 is a handheld laser particle counter, or dust measuring device, for measuring the concentration of particles in the air. The dust measuring device is battery powered to sample air quality in various environments.

- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust 80 MB internal memory and microSD card slot
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensor
Particle Counter PCE-PCO 2
PCE-PCO 2 is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature, dew point and relative humidity.

- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Temp. measuring range: 0 ... +50 °C / +32 ... +122 °F
- Humidity measuring range: 0 ... 100 % RH
- Built-in camera for image a
Particle Counter PCE-RCM 8
The particle counter PCE-RCM 8 performs many measuring tasks. For example, the particle counter can measure mass concentration, formaldehyde and TVOC. This particle counter is specially designed for indoor measurement.

- Formaldehyde in mg / m³
- Measurement of TVOC
- Temperature measurement
- Alarm function
- Mass concentration
Particle Counter PCE-RCM 15
The particle counter PCE-RCM 15 is specially designed to monitor the quality of indoor air. Among other things, the particle counter measures the parameters for PM1, PM2.5, PM10, TVOC, formaldehyde, humidity and temperature.

Measured quantity:
- Formaldehyde: 0 ... 1,999 mg / m³
- TVOC: 0 ... 9,999 mg / m³
- PM1, PM2.5, PM10: 0 ... 999 μg / m³
- Temperature: -10 ... 45°C / 14 ... 113°F (Only displays in °C)
- Humidity: 20 ... 99% RH
- 3 different display modes
- Alarm function
Particle Counter PCE-RCM 16
The particle counter PCE-RCM 16 is ideal for monitoring the air quality in homes, businesses or public buildings where people are staying. The 4.3-inch TFT display on the particle counter PCE-RCM 16 is dimensioned so that all measured values ​​can be read directly.

Metrics
- TVOC: 0.000 ... 9.999 mg / m³
- PM1, PM 2.5, PM10: 0 ... 999 μg / m³
- Temperature: 0 ... 50°C / 32 ... 122°F
- Humidity: 20 ... 90% rh
- CO2: 0 ... 5000 ppm / m³
Particle Counter PCE-MPC 10
PCE-MPC 10 is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature and relative humidity (RH).

- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: 0 ... +50 °C / +32 ... +122 °F
- Humidity measuring range: 0 ... 100 % RH
- 2" full-color LCD with user-friendly graphics
- Integrated data
Particle Counter PCE-MPC 20
The air quality monitoring particle counter PCE-MPC 20 is a particle counter that measures the particles in the atmosphere. The measurable particle sizes in the particle collector are 0.3, 2.5 and 10 μm.

- Measurable particle sizes: PM2.5 / PM10
- Measuring range Mass concentration: 0 ... 2000 μg / m³
- Measurable particle sizes: 0.3, 2.5 and 10 μm
- Display with graphic real-time diagram
- Data memory up to 5000 data sets
Particle Counter PCE-PQC 22EU
The particle counter PCE-PQC 22EU detects quickly where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Measuring range: 0.3 ... 25 μm
- Measuring channel sizes: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
- Counting efficiency: 50% at 0.3 μm 100% at > 0.45 μm according to JIS
- ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration
- Ethernet, USB
- CO2 sensor
- Incl. calibration certificate traceable to NIST ISO 21501-4 and
Particle Counter PCE-PQC 15EU
The particle counter PCE-PQC 15EU detects quickly where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Measuring range: 0.3 ... 75 μm
- Measuring channel sizes: 0.5, 1.0, 2.5, 5.0, 10.0, 30.0 μm
- Counting efficiency: 50% at 0.5 μm 100% at > 0.75 μm according to JIS
- ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration
- Ethernet, USB
- Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921