Home >> Measuring Instruments >> Flow Meter >> Ultrasonic Flow Meter PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS
Ultrasonic Flow Meter PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS

press to zoom
Ultrasonic Flow Meter PCE-TDS 100HMHS
Ultrasonic Flow Meter PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS

press to zoom
Ultrasonic Flow Meter PCE-TDS 100HMHS
Ultrasonic Flow Meter PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS

press to zoom
Ultrasonic Flow Meter PCE-TDS 100HMHS
Ultrasonic Flow Meter PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS

press to zoom
1/8

Flow Meter PCE-TDS 100HMHS

 
Order No: PCE-TDS 100HMHS

Ultrasonic Flow Meter PCE-TDS 100HMHS

Description 

The flow metre is a portable, easy-to-install measuring system that is used as part of a control measurement or to quickly figure out the flow in a pipeline. The transit time difference method is how the flow metre works. The flow metre is easy to understand in terms of how it measures. It takes less time to measure a pipe at an angle with the flow than straight up against the flow.

The longer it takes to go against the current, and the faster you go with it, the stronger it gets. So, the speed of the river has a direct effect on the difference in time between going with the flow and going against it. This effect is used by the flow metre to measure flow speed and flow. Electro-acoustic transducers send and receive short ultrasonic pulses through the fluid in the pipe. This is called the Pizo effect.

The transducers are spaced apart along the length of the measuring pipe on both sides. The sensors that don't damage the pipe are put on it and held in place with something like a cable tie. The flow rate is shown on the screen in a short time. The flow metre can be used to measure the flow in pipes made of metal, plastic, or rubber.

Liquids that can be measured include acetate, acetone, alcohol, ammonia, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R-12, gasoline, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1,1,1-trichloroethane, turpentine, distilled water, and salt water.

  • Ideal for retrofitting

  • Installation without process interruption

  • Easy construction

  • Accurate and reliable

  • No pressure loss

  • Maintenance-free, no moving parts

  • Wear-free

  • Portable devices for control measurements


Note: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software is sold separately.

Specifications 

Handheld measuring range                  -32 ... +32 m/s

Resolution                                               0.0001 m/s, 0.00033 ft/s

Accuracy for DN ≥ 50 mm:                    ±1.5 % of the measured value
for DN < 50 mm:                                     ±3.5 % of the measured value

Reproducibility                                        ±1.0 % of the measured value

Media                                                        All liquids with an impurity <5% and a flow >0.03 m³/h

 

Flow units                                                Cubic meter [m³]
                                                                  Litre [l]
                                                                  Gallon (USA) [gal]
                                                                  Imperial gallon (UK) [igl]
                                                                  Million USA gallon [mgl]
                                                                  Cubic foot [cf]
                                                                  Barrel (USA) [bal]
                                                                  Imperial barrel (UK) [ib]
                                                                  Oil barrel [ob] 

 

Time settings                                          per day [/d], per hour [/h], per minute [/m] and per second [/s]

Data logger                                             60,000 measurements

Interface                                                 USB (for online measurement and reading of the internal memory)

Protection                                               IP 52

Power supply                                         3 x AA NiMH rechargeable battery / 2100 mAh (at full charge 12h running time)
                                                                100 … 240 V AC 50/60 Hz

Dimensions                                            214 x 104 x 40 mm / 8.4 x 4.1 x 1.5"

Weight                                                    450 g / 15 oz

Sensor (only PCE-TDS 100 HS)           Nominal width DN 20 ... 108, 50 ... 720 mm / 0.8 ... 4.2, 1.9 ... 28.3"

Temperature of liquid                          -30 … 160 °C / -22 ... 320 °F

Dimensions                                           50 x 45 x 45 mm / 1.9 x 1.7 x 1.7"

Weight                                                   260 g / 9oz

Delivery Scope

1 x Flow Meter PCE-TDS 100HMHS
1 x TDS-HM on-rail sensor set (50 ... 720 mm /  0.8 ... 4.2" pipe diameter)
1 x TDS-HS on-rail sensor set (20 ... 108 mm / 1.9 ... 28.3" pipe diameter)
2 x 5 m / 16.4 ft connection cables
2 x Velcro cable ties
1 x Mains power adapter
1 x Ultrasonic contact gel
1 x PCE tape measure
1 x Plastic case
1 x Instruction manual

Note: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software is sold separately.